Input
Sensor type : Piezoresistive diaphragm
Measuring range : 10 bar ( Relative pressure )
Pressure overload range :
Pressure range
|
0.25 ... 0.4
|
0.6 ... 1
|
2
|
2.5 ... 4
|
6 ... 10
|
Overload range
|
2.5
|
3
|
4
|
7
|
15
|
Output
Output : 4 … 20 mA
Signal connection : 2-wire
Linear accuracy : ±0.3% of F.S.
Load resistance : ≦(Operating voltage-10 V ) / 0.02 A Ω
Output calibration(ZERO & SPAN) adjustment range : ±10% of Zero-point and full-scale
Response time : ≦5 ms
Environment
Measuring medium : Air / Liquid
Medium Temp. : 85℃;Cooling connector≦100℃(Option)
Operating Temp. : 85℃
Operating humidity : 100%RH
Storage temperature : -40 ... +100℃
Zero-point error : ±0.2% F.S. / 10 K
Measuring range tolerance : ±0.2% F.S. / 10 K
Electrical
Power supply : DC 10 ... 30 V
Current consumption : <20 mA
Overvoltage protection : ≦DC 33 V
Electrical connection : DIN 43650
Installation
Installation : Duct
Connect thread : Outside thread : 1/2″PT, 1/4″PT
Certification
Certification : CE
Protection
IP rating : IP65 (DIN 43650)
Electrical protection : ■ Over-voltage ■ Polarity ■ Short-circuit
Flutter test : 20 g(20 ... 5000 HZ)
Material
Housing : SUS304
Wetted part : SUS304
Sensor : SUS316L
Oil seal : Viton
Weight : 150 g
Measuring pressure for liquid and air / Research and Development / Laboratory / Processing engineering / Building / Liquid / Air pressure measurement / Machine devices / Water plant / Air devices