● Temperature range : -50 ... 200°C
● Special IC for RTD;High accuracy is assured
● TP02 with smaller volume so lesser space for installation is required
● High quality and low price
● DIN-rail type;Quick to install
Input
|
Input signal
|
RTD Pt100 Ω (3-wire)
|
Cable resistance
|
≦50 Ω (3 wires with the same resistance)
|
PT100Ω sensor current
|
<0.8 mA
|
ZERO adjustment range
|
±10%
|
SPAN adjustment range
|
±10%
|
Output
|
Signal
|
DC 4 ... 20 mA (2-wire)
|
Load resistance
|
≦(Supply voltage - 8 V) / 0.02 A Ω
|
Load resistance stability
|
±0.05% / 100 Ω
|
Power stability
|
±0.025% / V
|
Accuracy
|
Accuracy
|
±0.1% of F.S.
|
Temperature
|
Temperature drift
|
<±0.015% F.S. / °C
|
Calibration temperature
|
20 ... 28°C
|
Response time
|
<250 ms
|
Environmental
|
Medium
|
Air
|
Operating Temp.
|
-20 ... 60°C
|
Operating Humid.
|
0 ... 95%RH(Non-condensing)
|
Electrical
|
Power supply
|
DC 10 ... 30 V
|
Protection
|
Pt100 signal disconnection protection & output
|
>23 mA
|
Pt100 signal short circuit
protection & output
|
<3 mA
|
Output polarity protection
|
Yes
|
IP rating
|
Housing : IP30 / Terminal : IP10
|
Certification
|
Certification
|
CE
|
Material
|
Housing
|
ABS(UL94V-0)
|
Monitoring for long-distance temperature signal transmission / For industries in heating / Ventilation / Air conditioning / Cooling / Water power / Electricity, etc. / For process in agriculture / Green house / Environmental engineering / Food / Pharmaceutical industry