HF961 (No ionic halogenated compounds Cl + Br content test)

Ambient temperature :
|
25 ± 2 ℃
|
Humidity
|
50 ± 10% RH
|
Tester :
|
ion chromatograph (IC)
|
Calibration curve :
|
1, 5, 10, 15 ppm
|
Test requirements :
|
<500 ppm (L0)
|
Test results :
|
Br = 381 ppm
|
Quantitative Halides (Cl, Br) (IPC-TM-650, Test method 2.3.28.1)
Objective
The purpose of this test is to determine the total halide concentration of a flux.
Procedure:
Flux is dissolved to pre-determined concentration. Extracted solutions are then analyzed using an ion chromatograph with 3 to 5 level calibration. Total halide content is calculated and reported at Cl equivalent.
Results:
Total halides <0.05% Cl equivalent