Measurement Ranges: 
	23°C ± 5°C max. 80%R.H.  Accuracy: ±(%rdg +dgt) 
	
		
			
				| 
					 
						Measurement 
					 
				 | 
				
					 
						Range 
					 
				 | 
				
					 
						Resolution 
					 
				 | 
				
					 
						Accuracy 
					 
				 | 
				
					 
						Input 
					 
					
						Impedance 
					 
				 | 
				
					 
						Max. Input Voltage 
					 
				 | 
				
					 
						Open-Loop Voltage 
					 
				 | 
			
			
				| 
					 
						DE-2001D 
					 
				 | 
				
					 
						DE-2002D 
					 
				 | 
				
					 
						DE-2003D 
					 
				 | 
			
			
				| 
					 
						  
 (DCV) 
					 
				 | 
				
					 
						400mV 
					 
				 | 
				
					 
						0.1mV 
					 
				 | 
				
					 
						0.5%+1 
					 
				 | 
				
					 
						0.5%+1 
					 
				 | 
				
					 
						0.3%+1 
					 
				 | 
				
					 
						>100MΩ 
					 
				 | 
				
					 
						600V 
					 
				 | 
				
					 
						──── 
					 
				 | 
			
			
				| 
					 
						4V 
					 
				 | 
				
					 
						0.001V 
					 
				 | 
				
					 
						11MΩ 
					 
				 | 
			
			
				| 
					 
						40V 
					 
				 | 
				
					 
						0.01V 
					 
				 | 
				
					 
						0.75%+1 
					 
				 | 
				
					 
						10MΩ 
					 
				 | 
			
			
				| 
					 
						400V 
					 
				 | 
				
					 
						0.1V 
					 
				 | 
			
			
				| 
					 
						600V 
					 
				 | 
				
					 
						1V 
					 
				 | 
			
			
				| 
					 
						  
 (ACV) 
					 
				 | 
				
					 
						4V 
					 
				 | 
				
					 
						0.001V 
					 
				 | 
				
					 
						1%+5 
					 
				 | 
				
					 
						0.75%+5 
					 
				 | 
				
					 
						11MΩ; <50pF 
					 
				 | 
				
					 
						600V rms 
					 
				 | 
				
					 
						──── 
					 
				 | 
			
			
				| 
					 
						40V 
					 
				 | 
				
					 
						0.01V 
					 
				 | 
				
					 
						10MΩ; <50pF 
					 
				 | 
			
			
				| 
					 
						400V 
					 
				 | 
				
					 
						0.1V 
					 
				 | 
			
			
				| 
					 
						600V 
					 
				 | 
				
					 
						1V 
					 
				 | 
			
			
				| 
					 
						  
					 
				 | 
				
					 
						400Ω 
					 
				 | 
				
					 
						0.1Ω 
					 
				 | 
				
					 
						0.75%+2 
					 
				 | 
				
					 
						──── 
					 
				 | 
				
					 
						600V 
					 
				 | 
				
					 
						<3.4V 
					 
				 | 
			
			
				| 
					 
						4kΩ 
					 
				 | 
				
					 
						0.001kΩ 
					 
				 | 
				
					 
						0.75%+1 
					 
				 | 
				
					 
						<1.0V 
					 
				 | 
			
			
				| 
					 
						40kΩ 
					 
				 | 
				
					 
						0.01kΩ 
					 
				 | 
				
					 
						<0.7V 
					 
				 | 
			
			
				| 
					 
						400kΩ 
					 
				 | 
				
					 
						0.1kΩ 
					 
				 | 
			
			
				| 
					 
						4MΩ 
					 
				 | 
				
					 
						0.001MΩ 
					 
				 | 
				
					 
						2%+1 
					 
				 | 
			
			
				| 
					 
						40MΩ 
					 
				 | 
				
					 
						0.01MΩ 
					 
				 | 
				
					 
						5%+2 
					 
				 | 
			
			
				| 
					 
						  
 (BUZZER) 
					 
				 | 
				
					 
						400Ω 
					 
				 | 
				
					 
						0.1Ω 
					 
				 | 
				
					 
						The buzzer turns on for resistances lower
  than ≦50±20Ω. 
					 
				 | 
				
					 
						──── 
					 
				 | 
				
					 
						600V 
					 
				 | 
				
					 
						<3.4V 
					 
				 | 
			
			
				| 
					 
						  
 (DIODE) 
					 
				 | 
				
					 
						2V 
					 
				 | 
				
					 
						0.01V 
					 
				 | 
				
					 
						1%+1 
 (for measuring currents smaller than 1.0mA) 
					 
				 | 
				
					 
						──── 
					 
				 | 
				
					 
						600V 
					 
				 | 
				
					 
						<3.4V 
					 
				 | 
			
		
	
	  
	
		
			| 
				 
					Measurement 
				 
			 | 
			
				 
					Range 
				 
			 | 
			
				 
					Resolution 
				 
			 | 
			
				 
					Accuracy 
				 
			 | 
			
				 
					Input 
				 
				
					Impedance 
				 
			 | 
			
				 
					Max. Input Voltage 
				 
			 | 
			
				 
					Protection Fuse 
				 
			 | 
		
		
			| 
				 
					DE-2001D 
				 
			 | 
			
				 
					DE-2002D 
				 
			 | 
			
				 
					DE-2003D 
				 
			 | 
		
		
			| 
				 
					  
 (CAP) 
				 
			 | 
			
				 
					20nF 
				 
			 | 
			
				 
					0.01nF 
				 
			 | 
			
				 
					──── 
				 
			 | 
			
				 
					2%+5 
				 
			 | 
			
				 
					──── 
				 
			 | 
			
				 
					─── 
				 
			 | 
			
				 
					500mA / 660V 
  fuse 
				 
			 | 
		
		
			| 
				 
					200nF 
				 
			 | 
			
				 
					0.1nF 
				 
			 | 
		
		
			| 
				 
					2μF 
				 
			 | 
			
				 
					0.001μF 
				 
			 | 
		
		
			| 
				 
					20μF 
				 
			 | 
			
				 
					0.01μF 
				 
			 | 
		
		
			| 
				 
					200μF 
				 
			 | 
			
				 
					0.1μF 
				 
			 | 
		
		
			
				 
			 | 
			
				 
			 | 
			
				 
			 | 
			
				 
			 | 
			
				 
			 | 
			
				 
			 | 
			
				 
			 | 
			
				 
			 | 
			
				 
			 | 
		
	
	
		
			| 
				 
					Measurement 
				 
			 | 
			
				 
					Range 
				 
			 | 
			
				 
					Resolution 
				 
			 | 
			
				 
					Accuracy 
				 
			 | 
			
				 
					Voltage Drop 
				 
			 | 
			
				 
					Max. Input Current 
				 
			 | 
		
		
			| 
				 
					DE-2001D 
				 
			 | 
			
				 
					DE-2002D 
				 
			 | 
			
				 
					DE-2003D 
				 
			 | 
		
		
			| 
				 
					  
 (DCA) 
				 
			 | 
			
				 
					μA 
				 
			 | 
			
				 
					400μA 
				 
			 | 
			
				 
					0.1μA 
				 
			 | 
			
				 
					1%+2 
				 
			 | 
			
				 
					<0.17mV/μA 
				 
			 | 
			
				 
					400mA 
 (500mA / 660V) fuse 
				 
			 | 
		
		
			| 
				 
					4000μA 
				 
			 | 
			
				 
					1μA 
				 
			 | 
		
		
			| 
				 
					mA 
				 
			 | 
			
				 
					40mA 
				 
			 | 
			
				 
					0.01mA 
				 
			 | 
			
				 
					<3mV/mA 
				 
			 | 
		
		
			| 
				 
					400mA 
				 
			 | 
			
				 
					0.1mA 
				 
			 | 
		
		
			| 
				 
					A 
				 
			 | 
			
				 
					10A 
				 
			 | 
			
				 
					0.01A 
				 
			 | 
			
				 
					2%+2 
				 
			 | 
			
				 
					<0.04V/A 
				 
			 | 
			
				 
					10A 
				 
				
					(10A / 600V) fuse 
				 
			 | 
		
	
	*DE-2001D / 2002D
/ 2003D with fuse:500mA/660V & 10A/600V 
	  
	
		
			| 
				 
					Measurement 
				 
			 | 
			
				 
					Range 
				 
			 | 
			
				 
					Resolution 
				 
			 | 
			
				 
					Accuracy 
				 
			 | 
			
				 
					Voltage Drop 
				 
			 | 
			
				 
					Max. Input Current 
				 
			 | 
		
		
			| 
				 
					DE-2001D 
				 
			 | 
			
				 
					DE-2002D 
				 
			 | 
			
				 
					DE-2003D 
				 
			 | 
		
		
			| 
				 
					  
 (ACA) 
				 
			 | 
			
				 
					μA 
				 
			 | 
			
				 
					400μA 
				 
			 | 
			
				 
					0.1μA 
				 
			 | 
			
				 
					2%+20 
				 
			 | 
			
				 
					<0.17mV/μA 
				 
			 | 
			
				 
					400mA 
 (500mA / 660V) fuse 
				 
			 | 
		
		
			| 
				 
					4000μA 
				 
			 | 
			
				 
					1μA 
				 
			 | 
			
				 
					2%+5 
				 
			 | 
		
		
			| 
				 
					mA 
				 
			 | 
			
				 
					40mA 
				 
			 | 
			
				 
					0.01mA 
				 
			 | 
			
				 
					2%+20 
				 
			 | 
			
				 
					<3mV/mA 
				 
			 | 
		
		
			| 
				 
					400mA 
				 
			 | 
			
				 
					0.1mA 
				 
			 | 
			
				 
					2%+5 
				 
			 | 
		
		
			| 
				 
					A 
				 
			 | 
			
				 
					10A 
				 
			 | 
			
				 
					0.01A 
				 
			 | 
			
				 
					2.5%+20 
				 
			 | 
			
				 
					<0.04V/A 
				 
			 | 
			
				 
					10A 
				 
				
					(10A / 600V) fuse 
				 
			 | 
		
	
	*DE-2001D / 2002D
/ 2003D with fuse:500mA/660V & 10A/600V 
	
	  TEMP./Humidity: 
	- 
		Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
	
 
	- 
		Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)
	
 
	 
	  Dimension & Weight: 
	- 
		155(L)x74(W)x31(H)mm
	
 
	- 
		Approx.240g (Including battery)
	
 
	 
	  Accessories: 
	- 
		Battery AAA 1.5V x 2
	
 
	- 
		Instruction Manual x 1
	
 
	- 
		Test Lead (red + black) x 1