Measurement Ranges:
23°C ± 5°C max. 80%R.H. Accuracy: ±(%rdg +dgt)
Measurement
|
Range
|
Resolution
|
Accuracy
|
Input
Resistance
|
Max.
Input
Voltage
|
Sine
Wave (40Hz~500Hz)
|
AC
Voltage
|
400.0mV
|
0.1mV
|
1.0%+10
|
Around
11MΩ
|
1000V
rms
|
4.000V
|
0.001V
|
1.0%+5
|
40.00V
|
0.01V
|
Around
10MΩ
|
400.0V
|
0.1V
|
1000V
|
1V
|
DC
Voltage
|
400.0mV
|
0.1mV
|
0.5%+3
|
≥100MΩ
|
1000V
rms
|
4.000V
|
0.001V
|
Around
11MΩ
|
40.00V
|
0.01V
|
Around
10MΩ
|
400.0V
|
0.1V
|
1000V
|
1V
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Remark
|
Max.
Input
Voltage
|
Ω
Resistance
|
400.0Ω
|
0.1Ω
|
0.5%+3
|
*Open circuit Voltage around 0.4V
*The current changes in accordance with the resistance measured
|
1000V
rms
|
4.000kΩ
|
0.001kΩ
|
0.5%+2
|
40.00kΩ
|
0.01kΩ
|
400.0kΩ
|
0.1kΩ
|
4.000MΩ
|
0.001MΩ
|
40.00MΩ
|
0.01MΩ
|
1.5%+3
|
Measurement
|
Range
|
Resolution
|
Remark
|
Max.
Input
Voltage
|
Continuity
|
400.0Ω
|
0.1Ω
|
*Buzz emits when below around 90Ω±40Ω
*Open circuit voltage around 0.4V
|
1000V
rms
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Open
Circuit
Voltage
|
Max.
Input
Voltage
|
Diode
|
1.000V
|
0.001V
|
10%
|
Around
1.5V
|
1000V
rms
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Remark
|
Max.
Input
Voltage
|
Capacitance
|
50.00nF
|
0.01nF
|
1.5%+15
|
Accuracy is subject to press REL.⊿ to zero set before measurement.
|
1000V
rms
|
500.0nF
|
0.1nF
|
2.0%+5
|
5.000uF
|
0.001uF
|
5.0%+5
|
50.00uF
|
0.01uF
|
100.0uF
|
0.1uF
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Remark
|
Max.
Input
Voltage
|
Hz
Frequency
|
5.000Hz
|
0.001Hz
|
0.1%+3
|
Accuracy based on square wave.
|
1000V
rms
|
50.00Hz
|
0.01Hz
|
500.0Hz
|
0.1Hz
|
5.000kHz
|
0.001kHz
|
50.00kHz
|
0.01kHz
|
500.0kHz
|
0.1kHz
|
5.000MHz
|
0.001MHz
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Remark
|
Max.
Input
Voltage
|
Sine
Wave
|
AC
Current
|
400.0μA
|
0.1μA
|
1%+5
|
Frequency
range 40Hz~500Hz
|
400mA,fuse
0.63A/1000V
|
4000μA
|
1μA
|
40.00mA
|
0.01mA
|
400.0mA
|
0.1mA
|
4.000/10.00A
|
0.001/0.01A
|
10A,
fuse 10A/1000V
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Max.
Input Voltage
|
DC
Current
|
400.0μA
|
0.1μA
|
1%+3
|
400mA,
fuse 0.63A/1000V
|
4000μA
|
1μA
|
40.00mA
|
0.01mA
|
400.0mA
|
0.1mA
|
4.000/10.00A
|
0.001/0.01A
|
10A,
fuse 10A/1000V
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Temp
K-type (DE-243)
|
-55.0~0.0℃
|
0.1℃
|
2.0%+2℃
|
0.0~50.0℃
|
±2℃
|
50.0~700℃
|
0.1/1℃
|
2.0%+1℃
|
*Operation condition:0°C~ 50°C(32℉~122℉), <80% R.H.(no condensation)
Table of Functions:
Model
|
DE-240
|
DE-241
|
DE-242
|
DE-243
|
LCD display
|
4000
|
4000
|
4000
|
4000
|
True RMS
|
—
|
—
|
●
|
●
|
Auto range
|
●
|
●
|
●
|
●
|
Relative
|
●
|
●
|
●
|
●
|
Data hold
|
●
|
●
|
●
|
●
|
Backlight
|
—
|
●
|
●
|
●
|
Temperature
|
—
|
—
|
—
|
●
|
TEMP./Humidity:
-
Operation:-10°C~ 50°C(14℉~122℉)/<80% R.H.(no condensation)
-
Storage:-20°C~ 60°C(-4℉~140℉)/<70%R.H.(no condensation)
Dimension & Weight:
-
181(L)x91(W)x57(H)mm
-
Approx.380g (Excluding battery)
Accessories:
-
Battery AA 1.5V x 2
-
Instruction Manual x 1
-
Test Leads (red + black) x 1 set
-
Holster + Stand Rack x 1
Optional Accessories:
-
Thermocouple adaptor (NR-38)
-
K