Measurement Ranges:
23°C ± 5°C
max. 80%R.H. Accuracy: ±(%rdg +dgt)
Measurement
|
Range
|
Resolution
|
Accuracy / Responding
Hz
(sine wave)
|
Input
Resistance
|
Max.
Input
Voltage
|
DE-208E
|
DE-208F/208G
|
0.5%+10 (50Hz~60Hz)
|
ACV
|
660.0mV
(manual range)
|
0.1mV
|
1.0%+10 (40Hz~150Hz)
|
1.0%+10 (40Hz~150Hz)
|
≧100MΩ
|
1000V rms
|
6.600V
|
0.001V
|
1.0%+10 (40Hz~1kHz)
|
1.0%+10 (40Hz~1kHz)
|
Approx. 11MΩ
|
66.00V
|
0.01V
|
1.0%+10
(40Hz~5kHz)
2.0%+10
(5kHz~10kHz)
|
1.0%+10
(40Hz~3kHz)
|
Approx. 10MΩ
|
660.0V
|
0.1V
|
1000V
|
1V
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Input
Resistance
|
Max.
Input
Voltage
|
DCV
|
660.0mV
(manual range)
|
0.1mV
|
0.2%+5
|
≧100MΩ
|
1000V rms
|
6.600V
|
0.001V
|
Approx. 11MΩ
|
66.00V
|
0.01V
|
Approx. 10MΩ
|
660.0V
|
0.1V
|
1000V
|
1V
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Max.
Input
Voltage
|
Ω
Resistance
|
660.0Ω
|
0.1Ω
|
0.5%+5
|
1000V rms
|
6.600kΩ
|
0.001kΩ
|
66.00kΩ
|
0.01kΩ
|
660.0kΩ
|
0.1kΩ
|
6.600MΩ
|
0.001MΩ
|
1.0%+5
|
66.00MΩ
|
0.01MΩ
|
2.0%+5
|
Measurement
|
Range
|
Resolution
|
Remarks
|
Open-loop
Voltage
|
Max.
Input Voltage
|
Continuity
|
660.0Ω
|
0.1Ω
|
Buzzer
emits at around ≦30Ω
|
Approx. -3.3V
|
1000V rms
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Open-loop
Voltage
|
Max.
Input Voltage
|
Diode
|
2.000V
|
0.001V
|
1.0%+2
|
Approx.3.2V
|
1000V rms
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Remarks
|
Max. Input
Voltage
|
Capacitance
|
6.600nF
|
0.001nF
|
1.5%+10
|
Press “REL” for offset if some reading at
6.6nF/66nF ranges before measurement
|
1000V rms
|
66.00nF
|
0.01nF
|
660.0nF
|
0.1nF
|
6.600μF
|
0.001μF
|
66.00μF
|
0.01μF
|
2.0%+10
|
660.0μF
|
0.1μF
|
6.600mF
|
0.001mF
|
66.00mF
|
0.01mF
|
Measurement
|
Range
|
Resolution
|
Accuracy
|
Remarks
|
Max.
Input Voltage
|
Hz
Frequency
|
66.00Hz
|
0.01Hz
|
0.1%+3
|
Duty:
1%~98.9% (<10kHz3Vp-p) resolution:
0.01%.
Out of rating range display 0.00%(<0.9%) or OL (>98.9%)
|
1000V rms
|
660.0Hz
|
0.1Hz
|
6.600kHz
|
0.001kHz
|
66.00kHz
|
0.01kHz
|
660.0kHz
|
0.1kHz
|
6.600MHz
|
0.001MHz
|
66.00MHz
|
0.01MHz
|
Measurement
|
Range
|
Resolution
|
Accuracy / Responding
Hz
(sine wave)
|
Remarks
|
40Hz~5kHz
|
5kHz~10kHz
|
AC
|
μA
|
660.0μA
|
0.1μA
|
0.5%+10
|
1.2%+10
|
Protected
by a
630mA / 1000V fuse
|
μA
|
6600μA
|
1μA
|
mA
|
66.00mA
|
0.01mA
|
1.0%+10
|
mA
|
660.0mA
|
0.1mA
|
A
|
10A
|
0.01A
|
1.0%+10
|
1.5%+10
|
Protected
by a 10A / 1000V fuse
|
*11 ~ 20A stands with 30 sec. max.
Measurement
|
Range
|
Resolution
|
Accuracy
|
Remarks
|
DC
|
μA
|
660.0μA
|
0.1μA
|
0.5%+5
|
Protected
by a
630mA / 1000V fuse
|
μA
|
6600μA
|
1μA
|
mA
|
66.00mA
|
0.01mA
|
mA
|
660.0mA
|
0.1mA
|
A
|
10A
|
0.01A
|
1.0%+10
|
Protected
by a 10A / 1000V fuse
|
*11 ~ 20A stands with 30 sec. max.
ACA & ACV
accuracy in Peak mode:
Measurement
|
Range
|
Accuracy
|
Remarks
|
ACV
|
6.600V
|
2.0%+40
|
AC signals are valid ≧ 100 counts
|
66.00V
|
660.0V
|
1000V
|
ACuA
|
660.0μA
|
6600μA
|
ACmA
|
66.00mA
|
660.0mA
|
ACA
|
10A
|
★Temperature coefficient:
0.1 X (specified accuracy) / °C (<18 °C or >28 °C)
TEMP./Humidity:
-
Operation:0°C~ 50°C(32℉~122℉)/<80%
R.H.(no condensation)
-
Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no
condensation)
Dimension & Weight:
-
188(L)x95(W)x52(H)mm
-
Approx.405g (excluding battery)
Accessories:
-
9V Battery x1
-
Instruction Manual x1
-
Test Leads (black + red) x1