Measurement Ranges:
23°C ±5°C, 80% R.H. MAX) Accuracy:±(%rdg+dgt)
Measurement
|
Range
|
Resolution
|
True RMS Accuracy
|
Input Impedance
|
Maximum Input Measurement
|
Remarks
|
DE-3117
|
DE-3117C
|
(ACA)
|
400A
|
0.1A
|
1.8%+10
|
──
|
600A
|
|
600A
|
1A
|
1%+5
|

(DCA)
|
400A
|
0.1A
|
1.8%+10
|
──
|
600A
|
|
600A
|
1A
|
1%+5
|

(ACV)
|
4V
|
0.001mV
|
1.5%+10
|
Approx. 11MΩ
|
600Vrms
|
|
40V
|
0.01V
|
Approx. 10MΩ
|
400V
|
0.1V
|
1.5%+5
|
600V
|
1V
|

(DCV)
|
400mV
|
0.1V
|
0.75%+3
|
Approx. ≥100MΩ
|
600V
|
|
4V
|
0.001V
|
1%+3
|
Approx. 11MΩ
|
40V
|
0.01V
|
Approx. 10 MΩ
|
400V
|
0.1V
|
600V
|
1V
|

(Resistance)
|
400Ω
|
0.1Ω
|
1%+5
|
──
|
600V
|
*Open circuit voltage:approx.0.4V
*The measuring current changes in accordance with the
resistance measured
|
4kΩ
|
0.001kΩ
|
40kΩ
|
0.01kΩ
|
400kΩ
|
0.1kΩ
|
4MΩ
|
0.001MΩ
|
3%+5
|
40MΩ
|
0.01MΩ
|
5%+5
|

(BUZZER)
|
400Ω
|
0.1Ω
|
|
──
|
600V
|
The buzzer turns on for resistances below approx.100Ω
|

(Diode)
|
1.000V
|
0.001V
|
10%+5
|
──
|
600V
|
Open voltage:approx. 1.5V
|
(Capacitance)
|
50nF
|
0.01nF
|
──
|
3%+10
|
──
|
600V
|
Accuracy
is subject to zero set by Pressing REL. key before forwarding measurement.
|
500nF
|
0.1nF
|
5uF
|
0.001uF
|
50uF
|
0.01uF
|
5%+15
|
100uF
|
0.1uF
|
Hz
|
5.000Hz
|
0.001Hz
|
0.7%+5
|
|
──
|
600V
|
*Accuracy
in the case of sine wave.
*5.000Hz~100kHz:typical
above 5V rms
|
50.00Hz
|
0.01Hz
|
500.0Hz
|
0.1Hz
|
5.000kHz
|
0.001kHz
|
50.00kHZ
|
0.01kHz
|
100.0kHz
|
0.1kHz
|
※Remarks:The accuracy data for ACA,DCA is subject to the conductor to be
measured at the center of the iron core (clamp jaw)
Temp./Humidity :
-
Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation)
-
Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation)
Dimension& Weight :
-
189(L)x50(W,Max71)x30(H,Max47)mm
-
Approx.220g (Including battery)
Accessories :
-
Battery AAA 1.5V x2
-
Instruction Manual x1
-
Test Leads (red+black) x1
-
Carrying case x1
Optional Accessories :
-
AC Line Splitter(DE-10ALS)
*Applicable to electrical appliances small
current