Measurement Ranges: 
	(23°C ±5°C, 80% R.H. MAX) Accuracy:±(%rdg+dgt) 
	 
	
		
			
				| 
						Measurement 
					 | 
						Range 
					 | 
						Resolution 
					 | 
						AVG Accuracy 
					 | 
						True
  RMS 
					 
						Accuracy 
					 | 
						Input Impedance 
					 | 
						Open-Loop Voltage 
					 | 
			
				| 
						DE-3110 
					 | 
						DE-3110R 
					 | 
			
				| 
						
 
						  
						(ACA) 
					 | 
						40A 
					 | 
						0.01A 
					 | 
						1.5%+10 
					 | 
						──── 
					 | 
						
 | 
			
				| 
						400A 
					 | 
						0.1A 
					 | 
						1.5%+5 
					 | 
			
				| 
						
 
						  
						(DCA) 
					 | 
						40A 
					 | 
						0.01A 
					 | 
						1.5%+10 
					 | 
						──── 
					 | 
						
 | 
			
				| 
						400A 
					 | 
						0.1A 
					 | 
						1.5%+5 
					 | 
			
				| 
						  
						(ACV) 
					 | 
						4V 
					 | 
						0.001V 
					 | 
						1.0%+5 
					 | 
						11MΩ, <50pF 
					 | 
						
 | 
			
				| 
						40V 
					 | 
						0.01V 
					 | 
						10MΩ, <50pF 
					 | 
			
				| 
						400V 
					 | 
						0.1V 
					 | 
			
				| 
						600V 
					 | 
						1V 
					 | 
			
				| 
						  
						(DCV) 
					 | 
						4V 
					 | 
						0.001V 
					 | 
						0.75%+2 
					 | 
						11MΩ 
					 | 
						
 | 
			
				| 
						40V 
					 | 
						0.01V 
					 | 
						10MΩ 
					 | 
			
				| 
						400V 
					 | 
						0.1V 
					 | 
			
				| 
						600V 
					 | 
						1V 
					 | 
			
				| 
						  
						(Resistance) 
					 | 
						400Ω 
					 | 
						0.1Ω 
					 | 
						0.9%+2 
					 | 
						──── 
					 | 
						Approx <3.4V 
					 | 
			
				| 
						4kΩ 
					 | 
						0.001kΩ 
					 | 
						Approx <1.0V 
					 | 
			
				| 
						40kΩ 
					 | 
						0.01kΩ 
					 | 
						Approx <0.7V 
					 | 
			
				| 
						400kΩ 
					 | 
						0.1kΩ 
					 | 
			
				| 
						4MΩ 
					 | 
						0.001MΩ 
					 | 
						2%+2 
					 | 
			
				| 
						40MΩ 
					 | 
						0.01MΩ 
					 | 
						5%+2 
					 | 
			
				| 
						  
						(BUZZER) 
					 | 
						400Ω 
					 | 
						0.1Ω 
					 | 
						The buzzer turns on for resistances lower than 50Ω±25Ω 
					 | 
						──── 
					 | 
						Approx <3.4V 
					 | 
		
	
 
	
		※Remarks:The
accuracy data for ACA is subject to the conductor to be measured at the center
of the iron core (clamp jaw)
	
 
	  TEMP./Humidity:
	- 
		Operation:0°C~ 50°C(32℉~122℉)/<80% R.H.(no condensation) 
	
- 
		Storage:-10°C~ 60°C(14℉~140℉)/<70%R.H.(no condensation) 
	
	
	  Dimension & Weight:
	- 
		189(L)x50(W,Max71)x30(H,Max47)mm 
	
- 
		Approx.220g (Including battery) 
	
	
	  Accessories:
	- 
		Battery AAA 1.5V x2 
	
- 
		Instruction Manual x1 
	
- 
		Test Leads (red+black) x 1 
	
- 
		Carrying case x1 
	
	
	  Optional Accessories:
	- 
		AC Line Splitter(DE-10ALS)
 *Applicable to electrical appliances small current